By Kestrel

Kestrel 5100 Racing Weather Meter

R$ 1.807,00 - R$ 2.182,00
Shipping calculated at checkout.
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
Regular price R$ 1.807,00
Regular price R$ 2.257,00 Sale price R$ 1.807,00
Availability: 4 in stock
SKU: 0851RED
Measures:
Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Altitude (Barometric), Barometric Pressure, Pressure Trend, Dew Point Temperature, Wet Bulb Temperature (Psychrometric), Relative Humidity, Wind Chill, Density Altitude, Relative Air Density, Air Density, Moisture Content (Grains), Heat Stress Index, and Bluetooth (LiNK model)
Shipping:
Free Express Shipping in the USA
Global Shipping:
Discounted Global Shipping
Shipping Notice:
Ships in 1 business day
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price R$ 1.807,00
Regular price R$ 2.257,00 Sale price R$ 1.807,00

Ensure critical dial-in or tuning decisions are accurate with Kestrel 5100 Racing Weather Meter.

The compact, portable design makes this unit easy to take right to the track

Kestrel 5100 Meter at the trackThe Kestrel 5100 is just as accurate, reliable and user-friendly as the original Kestrel 4250. The Kestrel 5100 measures moisture content in grains, air density, relative air density, humidity and other critical factors. Count on it for the information you need to make perfect ET predictions and performance-maximizing tuning and jetting decisions. The compact, portable design makes this unit easy to take right to the track – exactly where you need to get the most accurate and race-relevant measurements. Pair it with the optional Kestrel Vane Mount for hands-free measurements logged over the course of the day. For maximum functionality, choose a Kestrel 5100 with LiNK to transmit live measurements to the Kestrel LiNK app on your iOS or Android device up to 100’ away (line of sight).

Affordable, accurate, portable and reliable, Kestrel meters have been proven at race tracks everywhere. Put the weather on your side – put a Kestrel in your toolbox.

The 5100 with LiNK Bluetooth Connectivity, gives you the option to transfer data wirelessly to an iOS (iPhone, iPad) device or Android smartphone or tablet when within range using the appropriate app (See Below). Also with the 5100 with LiNK Meter, you can transfer data wirelessly to a Windows or Mac computer using the optional Kestrel Bluetooth USB Dongle.

Who's using the Kestrel 5100?
  • Bracket Racers
  • Drag Racers
  • Pit Crews
  • Professional Auto Racing Teams
    Features:
    • Measures moisture content (grains), air density, relative air density (RAD), relative humidity, temperature, barometric pressure, wind speed and much more. 14 measurements in all.
    • Easy to read, high resolution screen (standard and NV backlit).
    • Time & date
    • Waterproof & floats
    • Exterior temperature, humidity & pressure sensors for fast & accurate readings
    • Humidity sensor can soon be calibrated in the field via cable or Dongle.
    • Min, Max & Average values
    • Automatically store measurements, when powered on or off
    • Manually store measurements with the press of a button
    • Customizable data storage - 10,000 data points
    • Graph & recall trends
    • Customize screens to display user-selected measurements
    • Data charting
    • Data upload to iOS & Android phones & tablets
    • Data upload to Windows or Mac computers with optional USB Data Cable
    • Data upload to Windows & Mac computers via wireless Bluetooth (LiNK Enabled Meters only with the optional Kestrel Dongle)
    • Languages: English, French, Spanish, German & Italian
    • User-replaceable impeller
    • impeller cover allows use of other functions & protecting the impeller
    • All instruments and accessories are completely assembled in the USA
        Measurement
        • Wind Speed
        • Current Wind Speed
        • Average Wind Speed
        • Maximum Wind Gust
        • Temperature
        • Altitude (Barometric)
        • Barometric Pressure
        • Pressure Trend
        • Dew Point Temperature
        • Wet Bulb Temperature (Psychrometric)
        • Relative Humidity
        • Wind Chill
        • Density Altitude
        • Relative Air Density
        • Air Density
        • Moisture Content (Grains)
        • Heat Stress Index
        • Bluetooth (LiNK model)

        Sensor Specifications:

        Wind Speed

        Units of Measure: mph | kt | B | m/s | ft/min / km/h 
        Specification Range:
        • 0.6 to 40.0 m/s
        • 118 to 7,874 ft/min
        • 2.2 to 144.0 km/h
        • 1.3 to 89.5 mph
        • 1.2 to 77.8 knots
        • 0 to 12 B*
        • 2-131.2 F/S*
        Operational Range:
        • 0.6 to 60.0 m/s
        • 118 to 11,811 ft/min
        • 2.2 to 216.0 km/h
        • 1.3 to 134.2 mph
        • 1.2 to 116.6 knots
        • 0 to 12 B*
        • 2-196.9 F/S*
        Resolution:
        • 0.1 m/s
        • 1 ft/min
        • 0.1 km/h
        • 0.1 mph
        • 0.1 knots
        • 1 B
        Accuracy (+/-): Larger of 3% of reading, least significant digit or 20 ft/min
        Notes: 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.

        Ambient Temperature:

        Units of Measure: Fahrenheit, Celsius
        Specification Range:
        • -20.0 to 158.0 °F
        • -29.0 to 70.0 °C
        Operational Range:
        • 14.0.0 to 131.0 °F
        • -10.0 to 55.0 °C
        Resolution:
        • 0.1 °F
        • 0.1 °C
        Accuracy (+/-):
        • 0.9 °F
        • 0.5 °C
        Notes: Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.

        Pressure:

        Units of Measure: inHg, hPA, mb
        Specification Range:
        • 25°C/ 77°F
        • 750-1100 hPa|mbar
        • 22.15-32.48 inHg
        • 10.88-15.95 PS
        Operational Range:
        • 0.30 to 48.87 inHg
        • 10.0 to 1654.7 hPa|mbar
        • 0.14 to 24.00 PSI
        • 14.0 to 131.0 °F -10.0 to 55.0 °C
        Resolution:
        • 0.1 hPa|mbar
        • 0.01 inHg
        • 0.01 PSI
        Accuracy (+/-):
        • 1.5 hPa|mbar
        • 0.044 inHg
        • 0.022 PSI
        Notes: Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

        Relative Humidity:

        Units of Measure: %
        Specification Range: 5 to 95% 25°C non-condensing
        Operational Range: 0 to 100% 
        Resolution: 0.1 %RH
        Accuracy (+/-): 3%RH
        Notes: To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.

        Calculated Measurements

         Altitude:

         

        Accuracy (+/-):
        • typical: 23.6 ft/7.2 m
        • - 50 to 1100 mBar
        • max: 48.2 ft/14.7 m
        • – 300 to 750 mBar
        Resolution:
        • 1ft
        • 1m
        Sensors employed:
        • Pressure
        • User Input (Reference Pressure)

        Dew Point:

        Accuracy (+/-):
        • 3.4 °F
        • 1.9 °C
        • 15-95% RH. Refer to Range for Temperature Sensor
        Resolution:
        • 0.1 °F
        • 0.1 °C
        Sensors employed:
        • Temperature
        • Relative Humidity

        Wet Bulb Temperature - Psychrometric

        Accuracy (+/-):
        • 3.2 °F
        • 1.8 °C
        Resolution:
        • 0.1 °F
        • 0.1 °C
        Sensors employed:
        • Temperature
        • Relative Humidity
        • Pressure

        Wind Chill:

        Accuracy:
        • 1.6 °F
        • 0.9 °C
        Resolution:
        • 0.1 °F
        • 0.1 °C
        Sensors employed:
        • Wind Speed
        • Temperature

        Density Altitude:

        Accuracy:
        • 226 ft
        • 69 m
        Resolution:
        • 1ft
        • 1m
        Sensors employed:
        • Temperature
        • Relative Humidity
        • Pressure

        Air Density:

        Accuracy:
        • 0.0002 lb/ft3
        • 0.0033 kg/m3
        Resolution:
        • 0.001 lbs/ft3
        • 0.001 kg/m3
        Sensors employed:
        • Temperature
        • Relative Humidity
        • Pressure

        Relative Air Density:

        Accuracy:
        • 0.3%
        Resolution:
        • 0.1%
        Sensors employed:
        • Temperature Relative
        • Humidity
        • Pressure

        Moisture Content | Humidity Ratio (“Grains”)

        Accuracy:
        • 3gpp
        • .4g/kg
        Resolution:
        • 0.1 gpp
        • 0.01 g/kg
        Sensors employed:
        • Temperature
        • Relative Humidity
        • Pressure

        Heat Index:

        Accuracy:
        • 7.1°F
        • 4.0°C
        Resolution:
        • 0.1 °F
        • 0.1 °C
        Sensors employed:
        • Temperature
        • Relative Humidity

        Downloads:

        Customer Reviews

        Based on 9 reviews
        67%
        (6)
        22%
        (2)
        11%
        (1)
        0%
        (0)
        0%
        (0)
        R
        Ronald Kuba

        Everything went smoothly, great product.

        A
        Andreas S.

        Top Gerät und schnelle Lieferung.

        M
        Mike H.

        Ordered the wrong one (without link) seamless exchange and great customer service.

        Thank You,
        Mike

        T
        Thomas E.

        Product as expected, knew what I sas buying. Was plesantly surprised by the very short delivery and shipping time.

        Thank you for the review! We do our best to ship our customers orders out fast.

        A
        Alexander P.

        DISPATCHED VERY QUICKLY AND WELL PACKED- EXCELLENT COMPANY TO DO BUSINESS WITH!