By Kestrel

Kestrel 2500NV Pocket Weather Meter

Regular price $756.000,00
Regular price $943.000,00 Sale price $756.000,00
Shipping calculated at checkout.
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
Availability: 13 in stock
SKU: 0825NV
Measures:
Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Barometric Pressure, Wind Chill, Altitude (Barometric), and Pressure Trend
Shipping:
Free Shipping in the USA
Global Shipping:
Discounted Global Shipping
Shipping Notice:
Ships in 1 business day
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price $756.000,00
Regular price $943.000,00 Sale price $756.000,00
With it's night vision preserving backlight, the 2500NV pocket weather meter is a great companion to have during day and night time excursions 

Predict fish and wildlife activity as well as when bad weather is headed your way with the three-hour pressure trend indicator. With its easy-to-use digital pressure altimeter, you have the perfect instrument for any outdoor activity - get conditions in seconds right in the palm of your hand. In addition to predicting weather activity, barometric pressure also influences a bullet’s trajectory, which is why the Kestrel 2500NV is used by shooters and hunters when accuracy is important.

Night Vision Preserving Backlight

The Kestrel 2500NV in Olive Drab with NV has a night-vision preserving backlight which helps users to sustain natural night vision. The NV's backlight incorporates an optical filter to reduce overall brightness and minimize blue and green spectrum light to preserve night vision. Additionally, NV backlights are also much dimmer than a standard backlight, making it more difficult to detect with the naked eye in night operations. This backlight appears soft greyish pink, not red, and is still in the visible spectrum, so it is not compatible with night-vision equipment. It takes 30 to 45 minutes for the average eye to adapt to darkness and maximize night vision. Even a short burst of white, yellow, green or blue light “bleaches out” the rod cell photo-receptors in the eye and causes night blindness until the entire adaptation process can take place again. Light in the red spectrum does not cause this “bleaching out”, preventing night blindness and night vision fatigue.

Features:
  • Simple 3-Button Control
  • High Contrast, Sunlight Readable Monochrome LCD Display
  • Backlight: Night Vision Preserving
  • Temperature Sensor (Patented External Isolated)
  • CR2032 Coin Cell Battery (Average Life 300 Hours)
  • Data Hold Function
  • Drop-Tested to MIL-STD-810G
  • Waterproof to IP67 (3'/1M for 30 minutes)
  • Kestrel Certificate of Conformity
  • Neck Lanyard
  • Patented Impeller and Sensor Technology
  • Slip-On Protective Cover
  • Time of Day
  • User-Replaceable Battery
  • User-Replaceable Impeller
  • Designed and built in the USA
Measurement
  • Wind Speed
  • Current Wind Speed
  • Average Wind Speed
  • Maximum Wind Gust
  • Temperature
  • Barometric Pressure
  • Wind Chill
  • Altitude (Barometric)
  • Pressure Trend

Sensor Specifications

Wind Speed
Selections: mph | kt | B | m/s | ft/min / km/h 
Specification Range:
  • 0.6 to 40.0 m/s
  • 118 to 7,874 ft/min
  • 2.2 to 144.0 km/h
  • 1.3 to 89.5 mph
  • 1.2 to 77.8 knots
  • 0 to 12 B*
  • 2-131.2 F/S*
Operational Range:
  • 0.6 to 60.0 m/s
  • 118 to 11,811 ft/min
  • 2.2 to 216.0 km/h
  • 1.3 to 134.2 mph
  • 1.2 to 116.6 knots
  • 0 to 12 B*
  • 2-196.9 F/S*
Resolution:
  • 0.1 m/s
  • 1 ft/min
  • 0.1 km/h
  • 0.1 mph
  • 0.1 knots
  • 1 B
Accuracy (+/-): Larger of 3% of reading, least significant digit or 20 ft/min
Notes: 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.

Ambient Temperature

Selections: Fahrenheit, Celsius
Specification Range:
  • -20.0 to 158.0 °F
  • -29.0 to 70.0 °C
Operational Range:
  • 14.0.0 to 131.0 °F
  • -10.0 to 55.0 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Accuracy (+/-):
  • 0.9 °F
  • 0.5 °C
Notes: Hermetically sealed, precision thermistor mounted externally and thermally isolated (US Patent 5,939,645) for rapid response. Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. Calibration drift negligible. Thermistor may also be used to measure temperature of water or snow by submerging thermistor portion into material -- remove impeller prior to taking submerged measurements and ensure humidity sensor membrane is free of liquid water prior to taking humidity-based measurements after submersion.

Pressure

Selections: inHg, hPA, mb
Specification Range:
  • 25°C/ 77°F
  • 750-1100 hPa|mbar
  • 22.15-32.48 inHg
  • 10.88-15.95 PS
Operational Range:
  • 0.30 to 48.87 inHg
  • 10.0 to 1654.7 hPa|mbar
  • 0.14 to 24.00 PSI
  • 14.0 to 131.0 °F -10.0 to 55.0 °C
Resolution:
  • 0.1 hPa|mbar
  • 0.01 inHg
  • 0.01 PSI
Accuracy (+/-):
  • 1.5 hPa|mbar
  • 0.044 inHg
  • 0.022 PSI
Notes: Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

Calculated Measurements

Wind Chill

Accuracy (+/-):
  • 1.6 °F
  • 0.9 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Wind Speed
  • Temperature

Barometric Pressure

Accuracy (+/-):
  • 0.07 inHg
  • 2.4 hPa|mbar
  • 0.03 PSI
Resolution:
  • 0.01 inHg
  • 0.1 hPa|mbar
  • 0.01 PSI
Sensors employed:
  • Pressure
  • User Input (Reference Altitude)

Altitude

Accuracy (+/-):
  • typical: 23.6 ft/7.2 m
  • from 750 to 1100 mBar
  • max: 48.2 ft/14.7 m
  • from 300 to 750 mBar
Resolution:
  • 1ft
  • 1m
Sensors employed:
  • Pressure
  • User Input (Reference Pressure)

Downloads:

Customer Reviews

Based on 2 reviews
50%
(1)
50%
(1)
0%
(0)
0%
(0)
0%
(0)
D
David R.

havent used yet

T
Tony V.

This meter is excellent and suits my needs perfectly. Navigation of the website and placing an order was also excellent as was the delivery time. It was in my mailbox before I knew it!