By Kestrel

Kestrel 5200 Professional Environmental Meter

$1.285.000,00 - $1.552.000,00
Shipping calculated at checkout.
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
Regular price $1.285.000,00
Regular price $1.605.000,00 Sale price $1.285.000,00
Availability: 6 in stock
SKU: 0852HVG
Measures:
Air Flow (CFM), Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Barometric Pressure, Pressure Trend, Relative Humidity, Altitude (Barometric), Dew Point Temperature, Wet Bulb Temperature (Psychrometric), Wind Chill, Heat Stress Index, Density Altitude, Air Density, Relative Air Density, Volume Air Flow, Delta-T, Evaporation Rate, Humidity Ratio (Grains), and Bluetooth (LiNK model)
Shipping:
Free Express Shipping in the USA
Global Shipping:
Discounted Global Shipping
Shipping Notice:
Ships in 1 business day
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price $1.285.000,00
Regular price $1.605.000,00 Sale price $1.285.000,00

The Kestrel 5200 eliminates the guesswork from difficult projects like pouring concrete, balancing HVAC systems, and monitoring job site conditions with its integrated specialty calculations.

The Kestrel 5200 offers advanced calculators and readings that are unique in the portable meter market and are designed to make your job easier. In addition to measuring current environmental conditions, the Kestrel 5200 tracks and logs over 10,000 sets of time-stamped data. Your data log can be transferred to a mobile device wirelessly with the LiNK wireless communication option and Kestrel LiNK app, or to a PC/MAC with either the accessory Kestrel LiNK Dongle or waterproof USB Data Transfer Cable (available separately).

Construction

The Kestrel 5200 has the American Concrete Institute Evaporation Rate nomograph built in, and displays the Evaporation Rate right on screen with no calculation or error-prone interpolation. With that information in hand, decisions about additives to the mix or curing adjustments can be made, prevent costly plastic shrinkage cracks of the slab. Plus, the Kestrel 5200 allows you to monitor wind-loading on booms and cranes, and even track the heat index on your work site to keep your workers safe.

HVAC

Volume air flow couldn’t get any easier than this. Simply input the duct shape and dimensions and traverse the Kestrel 5200 across the duct. You’ll get instantaneous and average volume air flow without the need for any geometry or calculations. readings that greatly assist in commissioning and performance balancing HVAC systems. While not a replacement for a balometer, the Kestrel 5200 is far less expensive and can save you time and money. The Kestrel 5200 also offers every commonly-used measurement of moisture content in air, making life easy to determine dehumidification needs.

LiNK (Bluetooth)

The 5200 with LiNK Bluetooth Connectivity, gives you the option to transfer data wirelessly to an iOS (iPhone, iPad) device or Android smartphone or tablet when within range using the appropriate app (See Below). Also with the 5200 with LiNK Meter, you can transfer data wirelessly to a Windows or Mac computer using the optional Kestrel Bluetooth USB Dongle.

Check out our Concrete Pro Jobsite Weather Kit. Includes a Small Tripod, Extension, Vane Mount and Hard Case.

    Features:

    • Lightweight, portable and simple set-up - can be used wherever readings are needed at the jobsite
    • Automatic Evaporation Rate Calculation based on ACI nomograph – no more charts or inaccurate guesswork
    • Comprehensive data-logging and extensive storage capabilities – document all job conditions to demonstrate compliance with protocol and protect against litigation
    • LiNK Wireless Bluetooth® Technology – view current and logged data and share job reports with the free Kestrel LiNK app on your mobile device
    • LiNK App Alerts – receive customizable alerts on a mobile device when changing weather conditions could pose a problem
    • Backlight - Switchable White/Red
    • Data Log Graph View
    • Drop-Tested to MIL-STD-810G
    • Integrated Flip Open Impeller Cover
    • LiNK Wireless Communication to Mobile Devices (Bluetooth low energy)*
    • Pressure Sensor
    • Temperature Sensor (Patented External Isolated)
    • Battery Life Indicator
    • Date & Time
    • Floats
    • Intuitive Tactile Up/Down/Enter Keypad
    • Minimum/Maximum/Average Reading
    • Relative Humidity Sensor
    • Waterproof to IP67 (3'/1M for 30 minutes)
    • User-Replaceable Impeller

    Who's using the Kestrel 5200?

    • Construction and Concrete Pouring
    • Facilities Management
    • HVAC & Air Conditioning Balancing
    • Remediation
      Measurement
      • Air Flow (CFM)
      • Wind Speed
      • Current Wind Speed
      • Average Wind Speed
      • Maximum Wind Gust
      • Temperature
      • Barometric Pressure
      • Pressure Trend
      • Relative Humidity
      • Altitude (Barometric)
      • Dew Point Temperature
      • Wet Bulb Temperature (Psychrometric)
      • Wind Chill
      • Heat Stress Index
      • Density Altitude
      • Air Density
      • Relative Air Density
      • Volume Air Flow
      • Delta-T
      • Evaporation Rate
      • Humidity Ratio (Grains)
      • Bluetooth (LiNK model)

      Sensor Specifications

       Wind Speed

      Units of Measure: mph | kt | B | m/s | ft/min / km/h 
      Specification Range:
      • 0.6 to 40.0 m/s
      • 118 to 7,874 ft/min
      • 2.2 to 144.0 km/h
      • 1.3 to 89.5 mph
      • 1.2 to 77.8 knots
      • 0 to 12 B*
      • 2-131.2 F/S*
      Operational Range:
      • 0.6 to 60.0 m/s
      • 118 to 11,811 ft/min
      • 2.2 to 216.0 km/h
      • 1.3 to 134.2 mph
      • 1.2 to 116.6 knots
      • 0 to 12 B*
      • 2-196.9 F/S*
      Resolution:
      • 0.1 m/s
      • 1 ft/min
      • 0.1 km/h
      • 0.1 mph
      • 0.1 knots
      • 1 B
      Accuracy (+/-): Larger of 3% of reading, least significant digit or 20 ft/min
      Notes: 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.

      Ambient Temperature

      Units of Measure: Fahrenheit, Celsius
      Specification Range:
      • -20.0 to 158.0 °F
      • -29.0 to 70.0 °C
      Operational Range:
      • 14.0.0 to 131.0 °F
      • -10.0 to 55.0 °C
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Accuracy (+/-):
      • 0.9 °F
      • 0.5 °C
      Notes: Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.

      Pressure

      Units of Measure: inHg, hPA, mb
      Specification Range:
      • 25°C/ 77°F
      • 750-1100 hPa|mbar
      • 22.15-32.48 inHg
      • 10.88-15.95 PS
      Operational Range:
      • 0.30 to 48.87 inHg
      • 10.0 to 1654.7 hPa|mbar
      • 0.14 to 24.00 PSI
      • 14.0 to 131.0 °F -10.0 to 55.0 °C
      Resolution:
      • 0.1 hPa|mbar
      • 0.01 inHg
      • 0.01 PSI
      Accuracy (+/-):
      • 1.5 hPa|mbar
      • 0.044 inHg
      • 0.022 PSI
      Notes: Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

      Relative Humidity

      Units of Measure: %
      Specification Range: 5 to 95% 25°C non-condensing
      Operational Range: 0 to 100% 
      Resolution: 0.1 %RH
      Accuracy (+/-): 3%RH
      Notes: To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.

      Calculated Measurements

      Altitude

       

      Accuracy (+/-):
      • typical: 23.6 ft/7.2 m
      • - 50 to 1100 mBar
      • max: 48.2 ft/14.7 m
      • – 300 to 750 mBar
      Resolution:
      • 1ft
      • 1m
      Sensors employed:
      • Pressure
      • User Input (Reference Pressure)

      Dew Point

      Accuracy (+/-):
      • 3.4 °F
      • 1.9 °C
      • 15-95% RH. Refer to Range for Temperature Sensor
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Sensors employed:
      • Temperature
      • Relative Humidity

      Wet Bulb Temperature - Psychrometric

      Accuracy (+/-):
      • 3.2 °F
      • 1.8 °C
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Sensors employed:
      • Temperature
      • Relative Humidity
      • Pressure

      Wind Chill

      Accuracy:
      • 1.6 °F
      • 0.9 °C
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Sensors employed:
      • Wind Speed
      • Temperature

      Density Altitude

      Accuracy:
      • 226 ft
      • 69 m
      Resolution:
      • 1ft
      • 1m
      Sensors employed:
      • Temperature
      • Relative Humidity
      • Pressure
      Sensors employed:
      • Temperature Relative
      • Humidity
      • Pressure

      Heat Index

      Accuracy:
      • 7.1°F
      • 4.0°C
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Sensors employed:
      • Temperature
      • Relative Humidity

      Air Density

      Accuracy:
      • 0.0002 lb/ft3
      • 0.0033 kg/m3
      Resolution:
      • 0.001 lbs/ft3
      • 0.001 kg/m3
      Sensors employed:
      • Temperature
      • Relative Humidity
      • Pressure

      Relative Air Density

      Accuracy:
      • 0.3%
      Resolution:
      • 0.1%
      Sensors employed:
      • Temperature Relative
      • Humidity
      • Pressure

      Volume Air Flow

      Accuracy:
      • 6.71%
      Resolution:
      • 1 cfm
      • 1 m3/hr
      • 1 m3/m
      • 0.1m3/s
      • 1 L/s
      Sensors employed:
      • Air Flow
      • User Input (Duct Shape & Size)

      Delta T

      Accuracy:
      • 3.2 °F
      • 1.8 °C
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Sensors employed:
      • Temperature
      • Relative Humidity
      • Pressure

      Evaporation Rate

      Accuracy:
      • 0.01 lb/ft2/hr
      • 0.06 kg/m2/hr
      Resolution:
      • 0.01 b/ft2/hr
      • 0.01 kg/m2/hr
      Sensors employed:
      • Wind Speed
      • Temperature
      • Relative Humidity
      • Pressure
      • User Input (Concrete Temperature)

      Downloads:

      Customer Reviews

      Based on 5 reviews
      100%
      (5)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      B
      Brandon S.

      Excellent meter very accurate!

      J
      John G.

      Great meter

      h
      holly g.

      nice lightweight and accurate meter received next day, I like the multiple functions! My HVAC guy says when using humidity function, breathing will affect it so set it down someplace away from humans! very accurate anemometer and temp

      C
      Chris C.

      This meter is awesome for use in the HVAC field.

      J
      John L.

      Unit worked grate for what I need to log down on my reports