By Kestrel

Kestrel 5400FW Fire Weather Meter Pro

Regular price ₸340,200.00
Regular price ₸424,800.00 Sale price ₸340,200.00
Shipping calculated at checkout.
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
Availability: Low stock: 2 left
SKU: 0854FWLVCORA
Measures:
Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Barometric Pressure, Relative Humidity, Wind Chill, Heat Stress Index, Density Altitude, Dew Point Temperature, Wind Direction, Naturally Aspirated Wet Bulb Temperature, Globe Temperature, Wet Bulb Temperature (Psychrometric), WBGT (Wet Bulb Globe Temperature), Thermal Work Limit (TWL), Probability of Ignition (PIG), Fine Dead Fuel Moisture (FDFM), Pressure Trend, and Bluetooth (LiNK model)
Shipping:
Free Express Shipping in the USA
Global Shipping:
Discounted Global Shipping
Shipping Notice:
Ships in 1 business day
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price ₸340,200.00
Regular price ₸424,800.00 Sale price ₸340,200.00

Kestrel 5400FW Fire Weather Meter Pro provides everything needed for reliable, accurate fire weather monitoring & WBGT heat safety measurement.

Measures Wet Bulb Globe Temperature (WBGT), Probability of Ignition (PIG), Fine Dead Fuel Moisture (FDFM), temperature, barometric pressure, humidity and much more. 20 measurements in all!

Wildland firefighters train to withstand the challenge of heavy exertion in extreme conditions. Extreme heat is a constant companion, and protective gear exacerbates the physical strain on a firefighter’s body. Building heat acclimatization is a critical component of training, but doing so without incurring heat illness or injury is equally critical and challenging. Heat injury is a constant danger with many incidents of heat related illness occurring every year. Heat illness prevention programs recommend measuring Wet Bulb Globe Temperature (WBGT) and implementing ACGIH work/recovery and hydration guidelines. WBGT is a much more complete measure of heat stress for the firefighter because it includes the effects of the radiant heat of the sun, fire, or hot surfaces. The Kestrel Fire Weather Meter PRO WBGT adds the WBGT measurement to the full capability of the Fire Weather Meter Pro – making it the complete tool for monitoring WBGT and fire weather during training or operations.  With pre-programmed ACGIH guidelines and alert settings to indicate when conditions have become extremely unsafe, the Kestrel Fire Weather Meter PRO with WBGT is the ultimate tool for increasing the safety of your crew.

Unlike other WBGT meters on the market, the Kestrel 5400 Fire Weather Pro WBGT is also a rugged, compact and easy-to-use portable weather station.  Clip the Kestrel 5400 into the secure tripod vane mount to set up a weather and heat safety monitoring station in seconds.  Measure wind speed, direction, temperature, humidity, pressure, dew point, elevation, density altitude, PIG, FDFM and more. In addition to measuring the current environmental conditions, the Kestrel 5400 Fire Weather Pro tracks and logs over 10,000 sets of time-stamped data. Your data log can be transferred to an iOS/Android device wirelessly with the LiNK wireless communication option and free Kestrel LiNK app, then exported and shared via email with ease. Data can also be transferred to a Windows/Mac device with either the accessory Kestrel LiNK Dongle or waterproof USB Data Transfer Cable (both sold separately). 

The Kestrel 5400 Fire Weather Meter Pro WBGT offers a large, high-resolution and contrast display and easy font readability. It also includes a built-in dual color backlight, extra-strong polycarbonate lens and AA battery operation, along with LiNK iOS and Android wireless connectivity and app support. Like all Kestrel meters, the Kestrel 5400 Fire Weather Pro WBGT is drop-proof, dust-proof, waterproof and able to withstand harsh environments without damage – so it can so it can work as hard as you do.

Kestrels have been put to the test in some of the harshest conditions on the planet. U.S. Special Forces, combat weather teams, wildland firefighters, smoke jumpers, Mt. Everest expeditions and auto pit crews are just a few who rely on a Kestrel to provide them with the crucial environmental data they need. There truly is no comparable environmental safety monitoring tool on the market. Adopt best safety practices for your team or workplace and add a Kestrel Heat Stress Tracker to your toolkit.

    Features:

    • Waterless WBGT accurately calculated from on-board digital sensors with no tedious setup or maintenance.
    • Large, hi-res, hi-contrast, graphic display is perfectly readable in the brightest sunlight and is backlit for use in low-light conditions.
    • Handheld, portable, data logger with customizable warning flag settings, graphing and measurement statistics.
    • Optional LiNK connectivity powered by Bluetooth Smart® provides wireless communication to mobile devices and computers and easy data export for sharing with crew members.
    • Rugged (drop tested to MIL-STD-810G standards), waterproof (sealed to IP67 standards) and floats.
    • User-Replaceable Impeller
    • Protective pouch, neck lanyard and Lithium AA battery included. • 5-year warranty.
        Measurement
        • Wind Speed
        • Current Wind Speed
        • Average Wind Speed
        • Maximum Wind Gust
        • Temperature
        • Barometric Pressure
        • Relative Humidity
        • Wind Chill
        • Heat Stress Index
        • Density Altitude
        • Dew Point Temperature
        • Wind Direction
        • Naturally Aspirated Wet Bulb Temperature
        • Globe Temperature
        • Wet Bulb Temperature (Psychrometric)
        • WBGT (Wet Bulb Globe Temperature)
        • Thermal Work Limit (TWL)
        • Probability of Ignition (PIG)
        • Fine Dead Fuel Moisture (FDFM)
        • Pressure Trend
        • Bluetooth (LiNK model)
        SENSORS
        SENSORS ACCURACY RESOLUTION SPECIFICATION RANGE NOTES
        Wind Speed |Air Larger of 3% of reading, least significant digit or 20 ft/min Speed 0.1 m/s
        1 ft/min
        0.1 km/h
        0.1 mph
        0.1 knots
        1 B*
        0.1 F/S*
        0.6 to 40.0 m/s
        118 to 7,874 ft/min
        2.2 to 144.0 km/h
        1.3 to 89.5 mph
        1.2 to 77.8 knots
        0 to 12 B*
        2-131.2*
        1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller
        Ambient Temperature 0.9 °F
        0.5 °C
        0.1 °F
        0.1 °C
        -20.0 to 158.0 °F
        -29.0 to 70.0 °C
        Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.
        Globe Temperature 2.5 °F
        1.4 °C
        0.1 °F
        0.1 °C
        -20.0 to 140.0 °F
        -29.0 to 60.0 °C
        Temperature inside 1in|25 mm black powder coated copper globe converted to Tg equivalent for standard 6 in|150 mm globe. Closest equivalence obtained with airflow greater than 2.2 mph|1 m/s.
        Relative Humidity 2%RH 0.1 %RH 10 to 90% 25°C noncondensing To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.
        Pressure 1.5 hPa|mbar
        0.044 inHg
        0.022 PSI
        0.1 hPa|mbar
        0.01 inHg
        0.01 PSI
        25°C/77°F
        700-1100 hPa|mbar
        20.67-32.48 inHg
        10.15-15.95 PSI
        Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.
        Compass
        1/16th Cardinal Scale
        0 to 360° 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout.

        CALCULATED MEASUREMENTS
        MEASUREMENT ACCURACY (+/-) RESOLUTION SENSORS EMPLOYED
        AHLU AHLU Accuracy derived from HLI accuracy accumulated over time. 1.0 Wind Speed,
        Temperature Globe Temperature,
        Relative Humidity
        Altitude typical: 23.6 ft/7.2 m
        from 750 to 1100 mBar
        max: 48.2 ft/14.7 m
        from 300 to 750 mBar
        1 ft 1 m Pressure,
        User Input (Reference Pressure)
        Barometric Pressure 0.07 inHg
        2.4 hPa|mbar
        0.03 PSI
        0.01 inHg
        0.1 hPa|mbar
        0.01 PSI
        Pressure, User Input (Reference Altitude)
        Crosswind & Headwind/Tailwind 7.1% 1 mph
        1 ft/min
        0.1 km/h
        0.1 m/s
        0.1 knots
        Wind Speed, Compass
        Density Altitude 226 ft
        69 m
        1 ft 1 m Temperature, Relative Humidity Pressure
        Dew Point 3.4 °F
        1.9 °C
        15-
        95% RH. Refer to Range for Temperature Sensor
        0.1 °F
        0.1 °C
        Temperature, Relative Humidity
        Heat Index 7.1°F
        4.0°C
        0.1 °F
        0.1 °C
        Temperature, Relative Humidity
        HLI 2.7 1.0 Wind Speed, Temperature Globe Temperature, Relative Humidity
        Outdoor Wet Bulb Globe Temperature (WBGT) 1.3 °F
        0.7 °C
        0.1 °F
        0.1 °C
        Wind Speed, Temperature Globe Temperature, Rative Humidity, Pressure
        Probability of Ignition (PIG) PIG Accuracy dependent on proximity of inputs to reference table steps. 10% Temperature, Relative Humidity
        THI (NRC) 1.5 °F
        0.8 °C
        0.1 °F
        0.1 °C
        Temperature, Relative Humidity
        THI (Yousef) 2.3 °F
        1.3 °C
        0.1 °F
        0.1 °C
        Temperature, Relative Humidity
        Thermal Work Limit (TWL) 10.9W/m2 0.1 °F
        0.1 °C
        TWind Speed,
        Temperature Globe Temperature,
        Relative Humidity,
        Pressure
        Wet Bulb Temperature - Psychrometric 3.2 °F
        1.8 °C
        0.1 °F
        0.1 °C
        Temperature, Relative Humidity Pressure
        Wet Bulb Temperature - Naturally Aspirated (NWB TEMP) 1.4 °F
        0.8 °C
        0.1 °F
        0.1 °C
        Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure
        Wind Chill 1.6 °F
        0.9 °C
        0.1 °F
        0.1 °C
        Wind Speed, Temperature
        ADDITIONAL PRODUCT INFO
        Display & Backlight Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight.
        Response Time & Display Update Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes.
        Data Storage & Graphical display Min/Max/Avg History Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points.
        data Upload & Bluetooth Data Connect Option Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC).
        Clock/Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
        Auto Shutdown User-selectable – Off, 15-60 minutes with no key presses.
        Languages English, French, German, Spanish.
        Certifications CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards.
        Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
        Battery Life AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use.
        Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
        Sealing Waterproof (IP67 and NEMA-6)
        Display & Battery Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading.
        Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
        Size & Weight 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included)

        Customer Reviews

        Based on 2 reviews
        100%
        (2)
        0%
        (0)
        0%
        (0)
        0%
        (0)
        0%
        (0)
        B
        Branden M.

        Awesome customer service!!

        J
        James W.

        The 5400 provides a more accurate reading than other WGBT units at a reasonable price. It is easy to use and calibrate.