Measures:
Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Wind Chill, Barometric Pressure, Altitude (Barometric), and Pressure Trend
Shipping:
Free Shipping in the USA
Global Shipping:
Discounted Global Shipping
Shipping Notice:
Ships in 1 business day
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price RM773.00 MYR
Regular price RM966.00 MYR Sale price RM773.00 MYR


Nature can turn on you at a moment's notice. This Kestrel 2500 measures vital weather conditions like wind speed and temperature, so you can plan ahead and stay safe in unpredictable situations.

Predict fish and wildlife activity as well as when bad weather is headed your way with the three-hour pressure trend indicator. With its easy-to-use digital pressure altimeter, you have the perfect instrument for any outdoor activity - get conditions in seconds right in the palm of your hand.

In addition to predicting weather activity, barometric pressure also influences a bullet’s trajectory, which is why the Kestrel 2500 is used by hunters when accuracy is important.

Available Orange (2500) with a standard backlight or in Olive Drab (2500NV) with Night Vision Preserving Backlight: The Kestrel 2500NV in Olive Drab with night-vision preserving backlight helps users to sustain natural night vision.

Features:
  • Simple 3-Button Control
  • High Contrast, Sunlight Readable Monochrome LCD Display
  • Backlight: Blue white
  • Temperature Sensor (Patented External Isolated)
  • CR2032 Coin Cell Battery (Average Life 300 Hours)
  • Data Hold Function
  • Drop-Tested to MIL-STD-810G
  • Waterproof to IP67 (3'/1M for 30 minutes)
  • Kestrel Certificate of Conformity
  • Neck Lanyard
  • Patented Impeller and Sensor Technology
  • Slip-On Protective Cover
  • Time of Day
  • User-Replaceable Battery
  • User-Replaceable Impeller
  • Waterproof & Floats
  • Designed and built in the USA
      Measurement
      • Wind Speed
      • Current Wind Speed
      • Average Wind Speed
      • Maximum Wind Gust
      • Temperature
      • Wind Chill
      • Barometric Pressure
      • Altitude (Barometric)
      • Pressure Trend

      Sensor Specifications

      Wind Speed
      Selections: mph | kt | B | m/s | ft/min / km/h 
      Specification Range:
      • 0.6 to 40.0 m/s
      • 118 to 7,874 ft/min
      • 2.2 to 144.0 km/h
      • 1.3 to 89.5 mph
      • 1.2 to 77.8 knots
      • 0 to 12 B*
      • 2-131.2 F/S*
      Operational Range:
      • 0.6 to 60.0 m/s
      • 118 to 11,811 ft/min
      • 2.2 to 216.0 km/h
      • 1.3 to 134.2 mph
      • 1.2 to 116.6 knots
      • 0 to 12 B*
      • 2-196.9 F/S*
      Resolution:
      • 0.1 m/s
      • 1 ft/min
      • 0.1 km/h
      • 0.1 mph
      • 0.1 knots
      • 1 B
      Accuracy (+/-): Larger of 3% of reading, least significant digit or 20 ft/min
      Notes: 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.

      Ambient Temperature

      Selections: Fahrenheit, Celsius
      Specification Range:
      • -20.0 to 158.0 °F
      • -29.0 to 70.0 °C
      Operational Range:
      • 14.0.0 to 131.0 °F
      • -10.0 to 55.0 °C
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Accuracy (+/-):
      • 0.9 °F
      • 0.5 °C
      Notes: Hermetically sealed, precision thermistor mounted externally and thermally isolated (US Patent 5,939,645) for rapid response. Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. Calibration drift negligible. Thermistor may also be used to measure temperature of water or snow by submerging thermistor portion into material -- remove impeller prior to taking submerged measurements and ensure humidity sensor membrane is free of liquid water prior to taking humidity-based measurements after submersion.

      Pressure

      Selections: inHg, hPA, mb
      Specification Range:
      • 25°C/ 77°F
      • 750-1100 hPa|mbar
      • 22.15-32.48 inHg
      • 10.88-15.95 PS
      Operational Range:
      • 0.30 to 48.87 inHg
      • 10.0 to 1654.7 hPa|mbar
      • 0.14 to 24.00 PSI
      • 14.0 to 131.0 °F -10.0 to 55.0 °C
      Resolution:
      • 0.1 hPa|mbar
      • 0.01 inHg
      • 0.01 PSI
      Accuracy (+/-):
      • 1.5 hPa|mbar
      • 0.044 inHg
      • 0.022 PSI
      Notes: Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

      Calculated Measurements

      Wind Chill

      Accuracy (+/-):
      • 1.6 °F
      • 0.9 °C
      Resolution:
      • 0.1 °F
      • 0.1 °C
      Sensors employed:
      • Wind Speed
      • Temperature

      Barometric Pressure

      Accuracy (+/-):
      • 0.07 inHg
      • 2.4 hPa|mbar
      • 0.03 PSI
      Resolution:
      • 0.01 inHg
      • 0.1 hPa|mbar
      • 0.01 PSI
      Sensors employed:
      • Pressure
      • User Input (Reference Altitude)

      Altitude

      Accuracy (+/-):
      • typical: 23.6 ft/7.2 m
      • from 750 to 1100 mBar
      • max: 48.2 ft/14.7 m
      • from 300 to 750 mBar
      Resolution:
      • 1ft
      • 1m
      Sensors employed:
      • Pressure
      • User Input (Reference Pressure)

      Downloads:

      Customer Reviews

      Based on 28 reviews
      89%
      (25)
      7%
      (2)
      4%
      (1)
      0%
      (0)
      0%
      (0)
      R
      Rune K.

      I have not used that one I got from you. I had one before that I liked very good.

      That one I got from you was broken at the shell who hides/close the battery.

      What can we do about that?

      Hi, Sorry to hear the battery door is broken. We are sending a replacement out right away! Thanks! Mitch

      J
      James B.

      Works exactly as described - more rugged than expected, would purchase again if needs allow.

      C
      Charmelle G.

      Excellent product. Met expectations and was exactly as described.

      A
      Allen H.

      Great service! Even shipped spare batteries for free.

      S
      Seth B.

      A good product at a good price with prompt delivery. I am glad that it was delivered via PO Box too.