By Kestrel

Kestrel 5200 Concrete Pro Jobsite Weather Kit

Regular price 5.204,00 kr
Regular price Sale price 5.204,00 kr
Shipping calculated at checkout.
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
Availability: In stock
SKU: 0852LVTCK
Measures:
Air Flow (CFM), Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Altitude (Barometric), Barometric Pressure, Dew Point Temperature, Wet Bulb Temperature (Psychrometric), Relative Humidity, Wind Chill, Heat Stress Index, Density Altitude, Air Density, Relative Air Density, Volume Air Flow, Delta-T, Evaporation Rate, Humidity Ratio (Grains), Bluetooth (LiNK model), and Pressure Trend
Shipping:
Free Express Shipping in the USA
Global Shipping:
Discounted Global Shipping
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price 5.204,00 kr
Regular price Sale price 5.204,00 kr
Avoid the expense of plastic shrinkage cracking by utilizing this easily transportable jobsite weather monitoring kit.

The Kestrel Concrete Pro Jobsite Weather Kit includes the Kestrel 5200 Professional Environmental Meter with LiNK, Rotating Vane Mount, and Portable Mini Tripod with Extension Rod.

The Kestrel 5200 offers advanced calculators and readings that are unique in the portable meter market and are designed to make your job easier. In addition to measuring current environmental conditions, the Kestrel 5200 tracks and logs over 10,000 sets of time-stamped data. Your data log can be transferred to a iOS/Android wirelessly with the LiNK wireless communication option and Kestrel LiNK app, or to a Windows or Mac computer.

  • Automatically calculates evaporation rate based on current weather conditions, and measures air velocity, air flow, air density, relative air density, delta T, and much more. 17 measurements in all!
  • New concrete Evaporation Rate Solver calculates the evaporation rate for different sets of environmental conditions and displays the risk for plastic shrinkage cracking (Low/Medium/High) allowing contractors to take steps to prevent cracking
  • Large, hi-res, hi-contrast, graphic display is perfectly readable in the brightest sunlight and is backlit for use in low-light conditions
  • Handheld, portable, data logger with on-screen graphing and measurement statistics
  • Optional LiNK connectivity powered by Bluetooth® low energy provides wireless communication to mobile devices and computers
Features:
  • Lightweight, portable and simple set-up - can be used wherever readings are needed at the jobsite
  • Automatic Evaporation Rate Calculation based on ACI nomograph – no more charts or inaccurate guesswork
  • Comprehensive data-logging and extensive storage capabilities – document all job conditions to demonstrate compliance with protocol and protect against litigation
  • LiNK Wireless Bluetooth® Technology – view current and logged data and share job reports with the free Kestrel LiNK app on your mobile device
  • LiNK App Alerts – receive customizable alerts on a mobile device when changing weather conditions could pose a problem
  • Backlight - Switchable White/Red
  • Data Log Graph View
  • Drop-Tested to MIL-STD-810G
  • Integrated Flip Open Impeller Cover
  • LiNK Wireless Communication to Mobile Devices (Bluetooth low energy)*
  • Pressure Sensor
  • Temperature Sensor (Patented External Isolated)
  • Battery Life Indicator
  • Date & Time
  • Floats
  • Intuitive Tactile Up/Down/Enter Keypad
  • Minimum/Maximum/Average Reading
  • Relative Humidity Sensor
  • Waterproof to IP67 (3'/1M for 30 minutes)
  • User-replaceable Impeller
Who's using the Kestrel 5200?
  • Construction and Concrete Pouring
  • Facilities Management
  • HVAC & Air Conditioning Balancing
  • Remediation
Measurement
  • Air Flow (CFM)
  • Wind Speed
  • Current Wind Speed
  • Average Wind Speed
  • Maximum Wind Gust
  • Temperature
  • Altitude (Barometric)
  • Barometric Pressure
  • Dew Point Temperature
  • Wet Bulb Temperature (Psychrometric)
  • Relative Humidity
  • Wind Chill
  • Heat Stress Index
  • Density Altitude
  • Air Density
  • Relative Air Density
  • Volume Air Flow
  • Delta-T
  • Evaporation Rate
  • Humidity Ratio (Grains)
  • Bluetooth (LiNK model)
  • Pressure Trend

Sensor Specifications

 Wind Speed

Units of Measure: mph | kt | B | m/s | ft/min / km/h 
Specification Range:
  • 0.6 to 40.0 m/s
  • 118 to 7,874 ft/min
  • 2.2 to 144.0 km/h
  • 1.3 to 89.5 mph
  • 1.2 to 77.8 knots
  • 0 to 12 B*
  • 2-131.2 F/S*
Operational Range:
  • 0.6 to 60.0 m/s
  • 118 to 11,811 ft/min
  • 2.2 to 216.0 km/h
  • 1.3 to 134.2 mph
  • 1.2 to 116.6 knots
  • 0 to 12 B*
  • 2-196.9 F/S*
Resolution:
  • 0.1 m/s
  • 1 ft/min
  • 0.1 km/h
  • 0.1 mph
  • 0.1 knots
  • 1 B
Accuracy (+/-): Larger of 3% of reading, least significant digit or 20 ft/min
Notes: 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.

Ambient Temperature

Units of Measure: Fahrenheit, Celsius
Specification Range:
  • -20.0 to 158.0 °F
  • -29.0 to 70.0 °C
Operational Range:
  • 14.0.0 to 131.0 °F
  • -10.0 to 55.0 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Accuracy (+/-):
  • 0.9 °F
  • 0.5 °C
Notes: Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.

Pressure

Units of Measure: inHg, hPA, mb
Specification Range:
  • 25°C/ 77°F
  • 750-1100 hPa|mbar
  • 22.15-32.48 inHg
  • 10.88-15.95 PS
Operational Range:
  • 0.30 to 48.87 inHg
  • 10.0 to 1654.7 hPa|mbar
  • 0.14 to 24.00 PSI
  • 14.0 to 131.0 °F -10.0 to 55.0 °C
Resolution:
  • 0.1 hPa|mbar
  • 0.01 inHg
  • 0.01 PSI
Accuracy (+/-):
  • 1.5 hPa|mbar
  • 0.044 inHg
  • 0.022 PSI
Notes: Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

Relative Humidity

Units of Measure: %
Specification Range: 5 to 95% 25°C non-condensing
Operational Range: 0 to 100% 
Resolution: 0.1 %RH
Accuracy (+/-): 3%RH
Notes: To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.

Calculated Measurements

Altitude

 

Accuracy (+/-):
  • typical: 23.6 ft/7.2 m
  • - 50 to 1100 mBar
  • max: 48.2 ft/14.7 m
  • – 300 to 750 mBar
Resolution:
  • 1ft
  • 1m
Sensors employed:
  • Pressure
  • User Input (Reference Pressure)

Dew Point

Accuracy (+/-):
  • 3.4 °F
  • 1.9 °C
  • 15-95% RH. Refer to Range for Temperature Sensor
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Temperature
  • Relative Humidity

Wet Bulb Temperature - Psychrometric

Accuracy (+/-):
  • 3.2 °F
  • 1.8 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Temperature
  • Relative Humidity
  • Pressure

Wind Chill

Accuracy:
  • 1.6 °F
  • 0.9 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Wind Speed
  • Temperature

Density Altitude

Accuracy:
  • 226 ft
  • 69 m
Resolution:
  • 1ft
  • 1m
Sensors employed:
  • Temperature
  • Relative Humidity
  • Pressure
Sensors employed:
  • Temperature Relative
  • Humidity
  • Pressure

Heat Index

Accuracy:
  • 7.1°F
  • 4.0°C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Temperature
  • Relative Humidity

Air Density

Accuracy:
  • 0.0002 lb/ft3
  • 0.0033 kg/m3
Resolution:
  • 0.001 lbs/ft3
  • 0.001 kg/m3
Sensors employed:
  • Temperature
  • Relative Humidity
  • Pressure

Relative Air Density

Accuracy:
  • 0.3%
Resolution:
  • 0.1%
Sensors employed:
  • Temperature Relative
  • Humidity
  • Pressure

Volume Air Flow

Accuracy:
  • 6.71%
Resolution:
  • 1 cfm
  • 1 m3/hr
  • 1 m3/m
  • 0.1m3/s
  • 1 L/s
Sensors employed:
  • Air Flow
  • User Input (Duct Shape & Size)

Delta T

Accuracy:
  • 3.2 °F
  • 1.8 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Temperature
  • Relative Humidity
  • Pressure

Evaporation Rate

Accuracy:
  • 0.01 lb/ft2/hr
  • 0.06 kg/m2/hr
Resolution:
  • 0.01 b/ft2/hr
  • 0.01 kg/m2/hr
Sensors employed:
  • Wind Speed
  • Temperature
  • Relative Humidity
  • Pressure
  • User Input (Concrete Temperature)

Downloads:

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)