By Kestrel

Kestrel 3550FW Pocket Fire Weather Meter with Bluetooth

Regular price 953,00 zł
Regular price Sale price 953,00 zł
Shipping calculated at checkout.
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
Availability: 9 in stock
SKU: 0835FWLCORA
Measures:
Wind Speed, Average Wind Speed, Maximum Wind Gust, Current Wind Speed, Temperature, Barometric Pressure, Relative Humidity, Wind Chill, Heat Stress Index, Dew Point Temperature, Pressure Trend, Altitude (Barometric), Wet Bulb Temperature (Psychrometric), Wind Direction, and Bluetooth
Shipping:
Free Shipping in the USA
Global Shipping:
Discounted Global Shipping
Shipping Notice:
Ships in 1 business day
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price 953,00 zł
Regular price Sale price 953,00 zł

Kestrel 3550FW Pocket Fire Weather Meter with Bluetooth offers unprecedented ease of use and robust capabilities.

The Kestrel 3550FW is much like the benchmark Kestrel 3000, but with a digital compass for wind direction, LiNK Bluetooth wireless communication and even more features.

Bluetooth connectivity

With its Compass and Bluetooth connectivity, the Kestrel 3550FW Fire Weather Meter will allow you to take your environmental readings on your meter and transfer the readings instantaneously to your mobile device using the free Kestrel app.

Once the data is stored in the Kestrel app, you can share your information using your mobile device. Send via email to a colleague or review stored data in-app. Also included is a spare Kestrel battery!

Easily share and send detailed weather reports with GPS location via text and email with the free Kestrel app.

Fighting wildfires and protecting lives, property and communities demands accurate weather monitoring and the ability to quickly share data to maximize crew safety and deploy resources. The Kestrel 3550FW paired with the free Kestrel app puts powerful tools for monitoring, logging, and sending important weather information for making the most informed decisions for fire management strategy.

Pocket sized, rugged, waterproof, affordable, easy-to-use and equipped with data logging capabilities and wireless data retrieval for monitoring and reporting, the Kestrel 3550FW is your trusted weather guide for fire management and safety.

Comprehensive Monitoring

Consistently accurate measurements of barometric pressure, altitude, dew point, heat stress index, relative humidity, temperature, wind speed and direction, wind chill, temperature and wet bulb readings.

Capture Real-Time Data

Easily view, and record data in real-time on a mobile device with the free Kestrel app.

Send Detailed Reports

Export and send detailed weather reports with GPS location via text or email for vital fire weather data management.

Reference Cards

Includes an easy-to-read Probability of Ignition (PIG) and Fine Dead Fuel Moisture (FDFM) reference card.

The new 3550FW meter has Bluetooth connectivity to pair with the Kestrel app for the ability to wirelessly view, share, and export weather data from a mobile device. Download the Kestrel app from the app store to take advantage of the all the features available.

Features:
  • Bluetooth Wireless Connectivity
  • Simple 3-Button Control
  • High Contrast, Sunlight Readable Monochrome LCD Display
  • Backlight (Blue white)
  • Temperature Sensor (Patented External Isolated)
  • CR2032 Coin Cell Battery (Average Life 300 Hours)
  • Data Hold Function
  • Drop-Tested to MIL-STD-810G
  • Waterproof to IP67 (3'/1M for 30 minutes)
  • Kestrel Certificate of Conformity
  • Neck Lanyard
  • Patented Impeller and Sensor Technology
  • Slip-On Protective Cover
  • Time of Day
  • User-Replaceable Battery
  • Waterproof Probability of Ignition Reference Card
  • User-Replaceable Impeller
  • Waterproof & Floats
  • Designed and built in the USA
Measurement
  • Wind Speed
  • Average Wind Speed
  • Maximum Wind Gust
  • Current Wind Speed
  • Temperature
  • Barometric Pressure
  • Relative Humidity
  • Wind Chill
  • Heat Stress Index
  • Dew Point Temperature
  • Pressure Trend
  • Altitude (Barometric)
  • Wet Bulb Temperature (Psychrometric)
  • Wind Direction
  • Bluetooth

Sensor Specifications

Wind Speed

Units of Measure: mph | kt | B | m/s | ft/min / km/h 
Specification Range:
  • 0.6 to 40.0 m/s
  • 118 to 7,874 ft/min
  • 2.2 to 144.0 km/h
  • 1.3 to 89.5 mph
  • 1.2 to 77.8 knots
  • 0 to 12 B*
  • 2-131.2 F/S*
Operational Range:
  • 0.6 to 60.0 m/s
  • 118 to 11,811 ft/min
  • 2.2 to 216.0 km/h
  • 1.3 to 134.2 mph
  • 1.2 to 116.6 knots
  • 0 to 12 B*
  • 2-196.9 F/S*
Resolution:
  • 0.1 m/s
  • 1 ft/min
  • 0.1 km/h
  • 0.1 mph
  • 0.1 knots
  • 1 B
Accuracy (+/-): Larger of 3% of reading, least significant digit or 20 ft/min
Notes: 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.

Ambient Temperature

Units of Measure: Fahrenheit, Celsius
Specification Range:
  • -20.0 to 158.0 °F
  • -29.0 to 70.0 °C
Operational Range:
  • 14.0.0 to 131.0 °F
  • -10.0 to 55.0 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Accuracy (+/-):
  • 0.9 °F
  • 0.5 °C
Notes: Hermetically sealed, precision thermistor mounted externally and thermally isolated (US Patent 5,939,645) for rapid response. Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. Calibration drift negligible. Thermistor may also be used to measure temperature of water or snow by submerging thermistor portion into material -- remove impeller prior to taking submerged measurements and ensure humidity sensor membrane is free of liquid water prior to taking humidity-based measurements after submersion.

Pressure

Units of Measure: inHg, hPA, mb
Specification Range:
  • 25°C/ 77°F
  • 750-1100 hPa|mbar
  • 22.15-32.48 inHg
  • 10.88-15.95 PS
Operational Range:
  • 0.30 to 48.87 inHg
  • 10.0 to 1654.7 hPa|mbar
  • 0.14 to 24.00 PSI
  • 14.0 to 131.0 °F -10.0 to 55.0 °C
Resolution:
  • 0.1 hPa|mbar
  • 0.01 inHg
  • 0.01 PSI
Accuracy (+/-):
  • 1.5 hPa|mbar
  • 0.044 inHg
  • 0.022 PSI
Notes: Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

Relative Humidity

Units of Measure: %
Specification Range: 5 to 95% 25°C non-condensing
Operational Range: 0 to 100% 
Resolution: 0.1 %RH
Accuracy (+/-): 3%RH
Notes: To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.

Calculated Measurements

Wind Chill

Accuracy (+/-):
  • 1.6 °F
  • 0.9 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Wind Speed
  • Temperature

Barometric Pressure

Accuracy (+/-):
  • 0.07 inHg
  • 2.4 hPa|mbar
  • 0.03 PSI
Resolution:
  • 0.01 inHg
  • 0.1 hPa|mbar
  • 0.01 PSI
Sensors employed:
  • Pressure
  • User Input (Reference Altitude)

Altitude

Accuracy (+/-):
  • typical: 23.6 ft/7.2 m
  • from 750 to 1100 mBar
  • max: 48.2 ft/14.7 m
  • from 300 to 750 mBar
Resolution:
  • 1ft
  • 1m
Sensors employed:
  • Pressure
  • User Input (Reference Pressure)

Dew Point

Accuracy (+/-):
  • 3.4 °F
  • 1.9 °C
  • 15-95% RH.
  • Refer to Range
    for Temperature Sensor
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Temperature
  • Relative Humidity

Wet Bulb Temperature - Psychrometric

Accuracy (+/-):
  • 3.2 °F
  • 1.8 °C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Wind Speed
  • Temperature

Heat Index

Accuracy (+/-):
  • 7.1°F
  • 4.0°C
Resolution:
  • 0.1 °F
  • 0.1 °C
Sensors employed:
  • Temperature
  • Relative Humidity

Downloads:

Customer Reviews

Based on 3 reviews
100%
(3)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
H
Heidi A.

Love the Kestrel 3550FW Fire Weather Meter with Bluetooth. It arrived quickly. Thank you!

W
Wil K.

There was a mix up with the product from the manufacturer but when Extreme Meters became aware of the dilemma, they replied promptly and shipped me a replacement. I will be shipping back the Kestrel with the packaging mistake in a return envelope they provided. Very good customer service!

R
Ronald H.

If you’re a firefighter this is the model you want, has all the features that are needed to stay on top of current fire weather conditions