Kestrel 5500FW Fire Weather Meter Pro
Couldn't load pickup availability
This all-in-one hand-held belt weather kit replacement provides all essential weather metrics, including PIG and FDFM.
Measure, log, track trends and expand capabilities with free Kestrel LiNK App.
The fast and easy tool for taking weather observations The Kestrel 5500 Fire Weather Meter Pro provides NIST-traceable accuracy, reliability and usability when it matters most. Measure every environmental condition plus PIG and FDFM and view trends with on-screen data graphing. Drop-proof, dust-proof, waterproof and able to withstand extreme environments without damage, your Kestrel Fire Weather meter can stand up to the abuses of work on a fire line wherever you’re assigned. A variety of carry pouch options makes it even easier to take your Kestrel Fire Weather meter with you. The Kestrel 5500 Fire Weather Meter Pro offers a large, high-resolution and contrast display and highly readable numerals. The Kestrel 5500 also includes a built-in dual color backlight, extra-strong polycarbonate lens and single AA battery operation. In addition to measuring the current environmental conditions, the Kestrel 5500 FWM tracks and logs over 10,000 sets of time-stamped data, providing a complete history of conditions on the fire from the moment you arrive. With optional LiNK wireless connectivity, your data log can be transferred to a Kestrel LiNK app (available on Android) for easy export and email to an FBAN or meteorologist. Data can also be downloaded to a PC with either the accessory Kestrel LiNK Dongle or waterproof USB Data Transfer Cable (Both sold separately).
Features:
- Measures wind speed and direction, temperature, humidity, barometric pressure and altitude.
- 14 total meteorological parameters measured, calculated and displayed real-time and stored in memory for monitoring trends.
- Probability of Ignition (PIG) and Fine Dead Fuel Moisture (FDFM) built-in for readings with no reference tables needed.
- Quick and consistently accurate measurements reduce the risk of human error possible with manual weather kits.
- Large, hi-res, hi-contrast, graphic display is perfectly readable in the brightest sunlight and is backlit for nighttime use.
- Optional LiNK connectivity powered by Bluetooth® low energy provides wireless communication to mobile devices and computers for in-depth analysis, export and easy communication to FBANs and other crews.
- Clip into the Kestrel Rotating Vane Mount to make the world’s most portable weather station (included with Pro model).
- Rugged (drop tested to MIL-STD-810G standards), waterproof (sealed to IP67 standards) and floats.
- Protective pouch, neck lanyard and Lithium AA battery included.
- User-Replaceable Impeller
- 5-year warranty.
Measurement |
---|
Sensor Specifications
Wind Speed |
|
Units of Measure: | mph | kt | B | m/s | ft/min / km/h |
Specification Range: |
|
Operational Range: |
|
Resolution: |
|
Accuracy (+/-): | Larger of 3% of reading, least significant digit or 20 ft/min |
Notes: | 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units. |
Ambient Temperature |
|
Units of Measure: | Fahrenheit, Celsius |
Specification Range: |
|
Operational Range: |
|
Resolution: |
|
Accuracy (+/-): |
|
Notes: | Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits. |
Pressure |
|
Units of Measure: | inHg, hPA, mb |
Specification Range: |
|
Operational Range: |
|
Resolution: |
|
Accuracy (+/-): |
|
Notes: | Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product. |
Relative Humidity |
|
Units of Measure: | % |
Specification Range: | 5 to 95% 25°C non-condensing |
Operational Range: | 0 to 100% |
Resolution: | 0.1 %RH |
Accuracy (+/-): | 3%RH |
Notes: | To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year. |
Compass |
|
Units of Measure: | Compass Heading in True or Magnetic |
Specification Range: | 0 to 360° |
Operational Range: | 0 to 360° |
Resolution: | 1° 1/16th Cardinal Scale |
Accuracy: | ±5° |
Notes: | 2-axis solid-state magneto resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout. |
Calculated Measurements
Altitude |
|
Accuracy (+/-): |
|
Resolution: |
|
Sensors employed: |
|
Dew Point |
|
Accuracy (+/-): |
|
Resolution: |
|
Sensors employed: |
|
Wet Bulb Temperature - Psychrometric |
|
Accuracy (+/-): |
|
Resolution: |
|
Sensors employed: |
|
Wind Chill |
|
Accuracy: |
|
Resolution: |
|
Sensors employed: |
|
Density Altitude |
|
Accuracy: |
|
Resolution: |
|
Sensors employed: |
|
Sensors employed: |
|
Heat Index |
|
Accuracy: |
|
Resolution: |
|
Sensors employed: |
|
Probability of Ignition (PIG) |
|
Accuracy: |
|
Resolution: |
|
Sensors employed: |
|
Downloads: