By Kestrel

Kestrel 5000AG Livestock Environmental Meter

$422.00 - $510.00
Shipping calculated at checkout.
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
Regular price $422.00
Regular price $527.00 Sale price $422.00
Availability: Low stock: 2 left
SKU: 0850AGHVG
Measures:
Air Flow (CFM), Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Barometric Pressure, Relative Humidity, Heat Stress Index, Wind Chill, Dew Point Temperature, Altitude (Barometric), Density Altitude, Wet Bulb Temperature (Psychrometric), Volume Air Flow, Temperature-Humidity Index (THI), and Bluetooth (LiNK model)
Shipping:
Free Express Shipping in the USA
Global Shipping:
Discounted Global Shipping
Shipping Notice:
Ships in 1 business day
Warranty:
5 year manufacturers warranty.
Complies with:
CE, UKCA, ROHS, WEEE
Regular price $422.00
Regular price $527.00 Sale price $422.00
A must-have tool for livestock producers, veterinarians and handlers.

Pocket-sized, rugged, accurate meter for assessing ventilation effectiveness, barn conditions, livestock heat stress, air speed, field microclimates, storage conditions, transportation safety, and more.

The Kestrel 5000AG is designed to meet the needs of livestock, agriculture and animal health professionals. Producers, growers, veterinarians, and consultants in every field of agriculture will gain vital information regarding micro-climate conditions needed to maximize performance and profitability. This lightweight, handheld, multi-function meter can be used inside and out for spot measurement of current conditions and also tracks and logs over 10,000 sets of time-stamped data. Clip the Kestrel 5000AG into the custom Kestrel 5 Series Rotating Vane Mount and you have a sturdy weather station that can be left in place for days or weeks.

Heat Stress Management with THI

THI, (Temperature-Humidity Index)  has been used for decades as a measure to classify heat stress risk in many livestock production and transportation operations. This measurement includes both temperature and relative humidity and is a basis for both strategic and tactical management practices which benefit animal health, productivity and well-being. The Kestrel 5000AG calculates and logs on-site THI based on user selection of either the NRC(National Research Council, 1971) or Yousef (Yousef, 1985) accepted THI calculations. Objective and accurate site-specific measurements are critical to ensuring a heat stress management strategy that is cost effective; and they're at your fingertips with the 5000AG.

Barn / Housing Ventilation Assessments:

Regardless of the type of barn/house design all livestock require proper ventilation and air movement to maximize health, growth, and comfort.  The Kestrel 5000AG provides air speed and air flow measurements to quickly quantify air movement in the vicinity of livestock, locate drafts, measure fan effectiveness and confirm duct discharge velocity. Volume air flow takes duct shape and dimensions into account and allows for accurate comparison of various locations in a system. No calculator is needed to determine airflow with the Kestrel 5000AG – a few quick menu picks and built-in averaging gives you accurate readings instantly.

Microclimate, Harvest and Storage Conditions:

Many livestock professionals also grow and store grains, hay and other feedstuffs. The Kestrel 5000AG can measure micro-climates around the farm to determine where mold and disease may be a problem, ensuring conditions are right for harvesting, drying, and storage. Leave the Kestrel 5000AG in place anywhere in th field, barn or greenhouse to get a graphical history of overnight conditions, (the Kestrel 5 Series Rotating Vane Mount and a ¼-20 camera clamp or tripod makes it easy).

Choose Kestrel LiNK Option to Add the Power of:

LiNK is Kestrel’s wireless data communication system, powered by Bluetooth® low energy. Choose the Kestrel 5000AG with LiNK option and you get full iOS, Android, PC and Mac app support.  See real-time readings on your phone or tablet on a customizable dashboard up to 100’ away (line of sight). Download stored data from your Kestrel to save or share it. Plus, you can update the firmware on your Kestrel when improvements are released.

Simple communication to Windows and Mac computers is provided through the optional LiNK USB Dongle or USB Data Transfer Cable. Download your data to view, analyze and archive.  Enables firmware update of Kestrel 5 series meters.

Note:  Bluetooth® low energy is built into all recent iOS and Android devices. PC and Mac connectivity require purchase of a Kestrel LiNK USB Dongle. Non-LiNK units can be connected to PC’s and Mac’s, but NOT phones and tablets, using the Kestrel USB Data Cable.

Kestrels have been put to the test in some of the harshest conditions on the planet. U.S. Special Forces, combat weather teams, wildland firefighters, smoke jumpers, Mt. Everest expeditions and auto pit crews are just a few who rely on a Kestrel to provide them with the crucial environmental data they need. Veterinarians have been purchasing Kestrel meters for years, knowing they will provide the readings they need immediately and reliably. Farmers know a Kestrel meter can help them avoid property damage, reduce livestock losses, and maximize productivity. Shouldn’t YOU be working with Kestrel?

Built for the Farm:
  • Rugged (drop tested to MIL-STD-810G standards – 10 drops from 4’).
  • Waterproof and dustproof (sealed to IP67 standards – 30’ submersion to 3’).
  • Small – carry in your pocket or store in your glove box.
  • High visibility case to avoid loss.
  • Large, hi-res, hi-contrast, graphic display is perfectly readable in the brightest sunlight and is backlit for use in low-light conditions.
  • Airflow impeller can be field-replaced without tools if damaged – patented!
  • Protective pouch, neck lanyard and Lithium AA battery included.
  • 5-year warranty.
  • Handheld, portable, data logger with on-screen graphing and measurement statistics.
  • Optional LiNK connectivity powered by Bluetooth® low energy provides wireless communication to mobile devices and computers.
  • Kestrel COC regarding accuracy of measurements
MEASUREMENTS DROP D2AG 5000AG 5500AG 5400AG
 Temperature yes yes yes yes
 Relative Humidity yes yes yes yes
 Heat Stress Index yes yes yes yes
 Temperature-Humidity Index (THI) yes yes yes yes
 Dew Point Temp. yes yes yes yes
 Wind Speed/Air Speed   yes yes yes
 Wind Chill   yes yes yes
 Wet Bulb Temp. (Psychrometric)   yes yes yes
 Station Pressure (Absolute Pressure)   yes yes yes
 Barometric Pressure   yes yes yes
 Altitude   yes yes yes
 Density Altitude   yes yes yes
 Volume Air Flow   yes yes  
 Wind Direction     yes yes
 Crosswind / Headwind / Tailwind     yes yes
 Delta T     yes yes
 Globe Temp.       yes
 Naturally Aspirated Wet Bulb Temp.       yes
 Wet Bulb Globe Temp. (WBGT)       yes
 Heat Load Index (HLI)       yes
 Accumulated Heat Load Units (AHLU)       yes
    Measurement
    • Air Flow (CFM)
    • Wind Speed
    • Current Wind Speed
    • Average Wind Speed
    • Maximum Wind Gust
    • Temperature
    • Barometric Pressure
    • Relative Humidity
    • Heat Stress Index
    • Wind Chill
    • Dew Point Temperature
    • Altitude (Barometric)
    • Density Altitude
    • Wet Bulb Temperature (Psychrometric)
    • Volume Air Flow
    • Temperature-Humidity Index (THI)
    • Bluetooth (LiNK model)

    Sensor Specifications

    Wind Speed

    Units of Measure: mph | kt | B | m/s | ft/min / km/h 
    Specification Range:
    • 0.6 to 40.0 m/s
    • 118 to 7,874 ft/min
    • 2.2 to 144.0 km/h
    • 1.3 to 89.5 mph
    • 1.2 to 77.8 knots
    • 0 to 12 B*
    • 2-131.2 F/S*
    Operational Range:
    • 0.6 to 60.0 m/s
    • 118 to 11,811 ft/min
    • 2.2 to 216.0 km/h
    • 1.3 to 134.2 mph
    • 1.2 to 116.6 knots
    • 0 to 12 B*
    • 2-196.9 F/S*
    Resolution:
    • 0.1 m/s
    • 1 ft/min
    • 0.1 km/h
    • 0.1 mph
    • 0.1 knots
    • 1 B
    Accuracy (+/-): Larger of 3% of reading, least significant digit or 20 ft/min
    Notes: 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.

    Ambient Temperature

    Units of Measure: Fahrenheit, Celsius
    Specification Range:
    • -20.0 to 158.0 °F
    • -29.0 to 70.0 °C
    Operational Range:
    • 14.0.0 to 131.0 °F
    • -10.0 to 55.0 °C
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Accuracy (+/-):
    • 0.9 °F
    • 0.5 °C
    Notes: Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.

    Pressure

    Units of Measure: inHg, hPA, mb
    Specification Range:
    • 25°C/ 77°F
    • 750-1100 hPa|mbar
    • 22.15-32.48 inHg
    • 10.88-15.95 PS
    Operational Range:
    • 0.30 to 48.87 inHg
    • 10.0 to 1654.7 hPa|mbar
    • 0.14 to 24.00 PSI
    • 14.0 to 131.0 °F -10.0 to 55.0 °C
    Resolution:
    • 0.1 hPa|mbar
    • 0.01 inHg
    • 0.01 PSI
    Accuracy (+/-):
    • 1.5 hPa|mbar
    • 0.044 inHg
    • 0.022 PSI
    Notes: Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

    Relative Humidity

    Units of Measure: %
    Specification Range: 5 to 95% 25°C non-condensing
    Operational Range: 0 to 100% 
    Resolution: 0.1 %RH
    Accuracy (+/-): 3%RH
    Notes: To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.

    Calculated Measurements

    Altitude

     

    Accuracy (+/-):
    • typical: 23.6 ft/7.2 m
    • - 50 to 1100 mBar
    • max: 48.2 ft/14.7 m
    • – 300 to 750 mBar
    Resolution:
    • 1ft
    • 1m
    Sensors employed:
    • Pressure
    • User Input (Reference Pressure)

    Dew Point

    Accuracy (+/-):
    • 3.4 °F
    • 1.9 °C
    • 15-95% RH. Refer to Range for Temperature Sensor
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Sensors employed:
    • Temperature
    • Relative Humidity

    Wet Bulb Temperature - Psychrometric

    Accuracy (+/-):
    • 3.2 °F
    • 1.8 °C
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Sensors employed:
    • Temperature
    • Relative Humidity
    • Pressure

    Wind Chill

    Accuracy:
    • 1.6 °F
    • 0.9 °C
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Sensors employed:
    • Wind Speed
    • Temperature

    Density Altitude

    Accuracy:
    • 226 ft
    • 69 m
    Resolution:
    • 1ft
    • 1m
    Sensors employed:
    • Temperature
    • Relative Humidity
    • Pressure
    Sensors employed:
    • Temperature Relative
    • Humidity
    • Pressure

    Heat Index

    Accuracy:
    • 7.1°F
    • 4.0°C
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Sensors employed:
    • Temperature
    • Relative Humidity

    Air Flow

    Accuracy:
    • 6.71%
    Resolution:
    • 1 cfm
    • 1 m3/hr
    • 1 m3/m
    • 0.1m3/s
    • 1 L/s
    Sensors employed:
    • Air Speed
    • User Input (Duct Shape
      & Size)

    THI (NRC)

    Accuracy:
    • 1.5 °F
    • 0.8 °C
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Sensors employed:
    • Temperature
    • Relative Humidity

    THI (Yousef)

    Accuracy:
    • 2.3 °F
    • 1.3 °C
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Sensors employed:
    • Temperature
    • Relative Humidity

    Delta T

    Accuracy:
    • 3.2 °F
    • 1.8 °C
    Resolution:
    • 0.1 °F
    • 0.1 °C
    Sensors employed:
    • Temperature
    • Relative Humidity
    • Pressure

    Downloads:

    Customer Reviews

    Based on 1 review
    100%
    (1)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    M
    Mitch C.

    Works great thanks